Powerflushing

Using our thermal imaging camera, we are able to see the problems and concentrate on the right areas during a powerflush, please scroll through our latest job images

blocked

blocked

totally blocked, thought this one was destined for a replacement

cleaned

cleaned

Given the all clear !

blocked

blocked

radiator hot at the top but cold in the middle

cleaned

cleaned

blocked

blocked

the owner had just flushed this in the garden with a hose, no need to do that one he said

cleaned

cleaned

After chemical flushing

blocked

blocked

cleaned

cleaned

blocked

blocked

blocked top left,

cleaned

cleaned

Powerflush
Full system powerflush

We can carry out a full system powerflush subject to a survey of your system, a powerflush can be needed for a variety of reasons, it  can be your radiators are not as you would expect, there are cold spots on the radiators, poor circulation, boiler banging, black sludge found. We use a heat camera to identify problem areas that could be resolved with a powerflush, along with testing for total dissolved solids and also ensuring the correct PH, we use a Kamco powerflushing pump, in conjuction with a magnacleanse flushing filter unit, and using quality chemicals following Kamco and British Standards guidlines ensuring that your system has the best system flush possible for your money, please look at our pictures in the gallery below for tools of the trade and what really goes on, and in our gallery of radiators for success stories in system flushing.

 

Here is our Kamco Powerflush pump and magnacleanse system in action. We have just completed a system flush where the initial radiator temperatures were around 32c at the top, with no heat at the bottom, some radiators were not working at all, the boiler was cutting in and out, there was no heat in the property and the user had electric fires to boost the heat.

it was crying out for a system flush, After powerflushing, we had 63c with on average a 8c difference between top and bottom, we removed over half a bucket of sludge from the system, this was our most challenging powerflush yet.

 

 

Boiler only
powerflush

 

This can be where you have a combination boiler with poor hot water, or noisy,

it could be heat only with poor circulation, here we are powerflushing a Viessmann 100 with poor hot water issues, we flush the boiler and then the plate heat exchanger, whilst we so far have had 100% success, this cannot always be guaranteed.

Specific area attention
we can offer a powerflush to a specific area of the system as you require, this will be carried out using our Kamco Powerflush and Magnacleanse unit to help remove the blockages.

 

 

kamco powerflush.JPG 2015-1-21-21:13:20

kamco powerflush.JPG 2015-1-21-21:13:20

using the Kamco Pump, we ensure the flow rate is as good as it can be to clean the heating system that just using the magnacleanse cannot do

clean mag.jpg

clean mag.jpg

clean magnacleanse magnet

sludge.jpg

sludge.jpg

after just one radiator, the debris is collected

tds.jpg

tds.jpg

testing the total disolved solids to ensure all is clear from the system,

ph meter.jpg

ph meter.jpg

Testing the PH of the water to ensure no acid is left in the system, which would cause rotting in the radiators

boiler flush

 Please take time to read the flushing disclaimer file above.

We are fully trained by Kamco on system cleaning methods and powerflushing, use all the latest powerflushing and testing equipment available, please see our training  certificate.

Why  not visit the www.kamco.co.uk website for further information

regarding powerflushing.